Standardization of acquisition protocols using PET/CT with 18F-Choline in prostate cancer.

Unidad PET CETIR ASCIRES Grupo biomédico, Esplugues de Llobregat, Barcelona, España. Electronic address: jrgarcia@cetir.es. Unidad PET CETIR ASCIRES Grupo biomédico, Esplugues de Llobregat, Barcelona, España.

Revista espanola de medicina nuclear e imagen molecular. 2020;(4):204-211
Full text from:

Abstract

AIM: To standardize acquisition protocols for 18F-Choline PET/CT to prevent from urine interference, to determine the best time point for the whole-body study, and to assess whether "dual point" acquisition allows for differentiating malignant vs. benign lesions. METHODS One hundred consecutive patients with prostate cancer were prospectively studied. Immediately after 18F-Choline injection, a pelvis study was acquired, and a whole-body was subsequently obtained 1 and 2 hours p.i. Mean SUVmax was obtained in regions and for every sequential imaging. Mean analysis (χ2) and SUV percentage change (2/1 hours; 1 hours/0 min) were obtained. Metabolic pattern dynamics were assessed: accumulative vs. clearance. Patient follow-up after therapy and directed classification whenever ethically possible were performed. RESULTS Fifty-three prostate foci, without disturbing urinary activity was ever found on early images. Accumulative pattern in 42, with percentage increase was: 0 min/1 hour: +16.7% (χ20.94); 1/2 hours: +10,0% (χ2 0.83). Clearance pattern in 11, with percentage decrease: 0 min/1 hour: -21.4% (χ20.91): -7.7% (χ20.85), corresponding in 7 to initial staging and in 4 post-radiotherapy biochemical recurrence. Every infradiaphragmatic uptake (n: 24) showed accumulative pattern, with percentage increase of +9.1% (χ20.97), all of them depicted on early imaging. As for 12 supradiaphragmantic uptake, 8 of them showed clearance pattern with percentage decrease: -13.0% (χ20.95). Accumulative pattern showed in 4 of them with percentage increase +13.0% (χ2 0.96), thus being assessed as invasive/malignant. Every bone uptake (n: 18) showed accumulative pattern, with percentage increase: +17.1% (χ20.95), all of them depicted on 1 hour imaging. CONCLUSIONS As for prostate assessment is concerned, dual point at 0 min/1 hour proved to be the best procedure. As for supradiaphragmatic lymph-nodes detection, dual point with 1/2 hours performed best. As for infradiaphragmatic and bone involvement, as well as for inconclusive findings, the 2 hour imaging increased our diagnostic confidence.

Methodological quality

Publication Type : Clinical Trial

Metadata